SUTO iTEC products play a vital role in the measurement and monitoring of compressed air and gas systems in many applications for leading European and Asian companies. Customers can expect cutting-edge technology at a reasonable price.
SUTO iTECH categories
Flow and consumption
Measuring and monitoring the flow and consumption of compressed air and other non-flammable gases will give you a perfect overview of the economics of compressed air production.
- Easy setup
- For pipes and tubes from DN 8 to DN 300
- Also ATEX/EX measuring instruments
- Different types of outlets
Pressure dew point
(relative humidity, absolute humidity, ppm)
Moisture in the piping can cause damage to equipment, compromise production quality and cause other potential problems.
By measuring pressure dew point, relative and absolute humidity, we can determine the condition of the compressed air in the system on a one-time or continuous basis and protect production equipment.
For measurements we use:
- separate pressure sensors
- dew point pressure gauges with display
- portable mobile devices with their own memory
- alarm output
- range -100 °C to +50 °C
OIL CONTENT METERS
Measurement of residual oil vapour content should not be missing in all cleanliness-intensive operations such as pharmaceuticals, food production, paint shops, electrical production.
Even the use of modern oil-free compressors and sophisticated filtration will not ensure that no oil enters the system in all cases.
If you need to be sure, if you want to be alerted by an alarm in time and have a record of the oil content at any point in the system, then the most suitable solution is a stable or portable S 120.
- Can be used for permanent or portable applications
- Measuring allows from 0.003 mg/m³
- Easy and quick connection via sampling tubing
- Output signals: – 4 … 20 mA, RS-485, Modbus/RTU
- Relay switch (NO)
- PID sensor for highest accuracy
- Service indication and alarm via LED
- Connectible to SUTO displays and third party data loggers as well
- Integrated 5″ touch screen and data logger (optional)
Measurement in practice - FILCO, spol. s.r.o.
Excerpt hereMECHANICAL IMPURITY METER
Measurement of the system condition in terms of mechanical impurities is a necessity in some operations where ISO 8573-4 must be complied with.
A new generation measuring instrument S 130 is available.
- Easy connection to compressed air via 6 mm hose with quick coupling
- Can be used as a portable or stationary tool
- Particle size range d: 0.1 <d <= 5.0 um
- Optional integrated 5″ touch screen with data logger
- Measures according to ISO 8573-4
Output signals:
- RS-485, Modbus/RTU
- Relay switch (NO)
Connectable to SUTO displays and third party data loggers, displays and controllers.
COMPRESSED AIR LEAK METER
Leaks in the compressed air system seriously increase the cost of its production. Early and regular leak detection and rapid repair based on detected and located leaks will prevent financial losses.
- Simple leak detection
- Long battery life
- Proprietary software
- Additional features
S600 METER - ALL IN ONE - PORTABLE DESIGN
Oil, moisture, mechanical impurities. All this is detected, measured and logged by the state-of-the-art S 600 portable instrument.
- The all-in-one device measures particle concentration, dew point and oil vapour
- It also measures temperature and pressure
- Software-controlled measurement facilitates accurate results
- Report generator produces PDFs for audits
- Portable and compact design
- Compressed air connection via 6 mm pipe
- Integrated data logger stores data for later analysis
- Dew point measurement from -100 to +20 °C Td
- Oil vapor measurement from 0.003 to 10,000 mg/m³
- Particle measurement from 0.1 <d <5.0 um
METER S601 - ALL IN ONE - STATIONARY
Oil, moisture, mechanical impurities, pressure and temperature. Continuous monitoring of compressed air parameters.
- All-in-one device measures particle concentration, dew point and oil vapour
- Also measures temperature and pressure
- Automatic report generation
- Includes Modbus/RTU (RS 485) and Modbus TCP (Ethernet) output
- Compact design and easy setup
- Compressed air connection via 6 mm pipe
- Integrated data logger stores data for later analysis
- Dew point measurement from -100 … +20 °C Td
- Oil vapour measurement from 0.003 to 10,000 mg/m³
Particle measurement in two versions:
- A1260: 0.3 <d <5.0 um
- A1263: 0.1 <d <5.0 um
DATA LOGGER - MANY FUNCTIONS
- 5″ high-resolution colour touch screen
- All SUTO and compatible sensors are compatible with third party products
- 16 x Modbus inputs (58 standard or 108 optional channels)
- 2 x SDI inputs (20 channels)
- 2 x analogue and pulse input (4 channels)
- Plus 10 virtual channels for calculations such as kW/m³/min or differential pressure
- 2 wall covers available: 4 cable glands or 7 cable glands
- USB interface for data transfer to data stick or PC
- RS-485 (Modbus/RTU) and Ethernet (Modbus TCP) interfaces to the factory automation system
- Sensor power supply 10 W (24 VDC)
- Data logger (S331 only): 100 million values
- Alarm monitoring with 2 relay outputs
- Integrated web server for remote monitoring
- Quick setup
- Various system expansion options
- Compressor run time monitoring
MONITOR - ATTRACTIVE PRICE
In cases where the measuring instruments are located in inaccessible locations, a display located in a more accessible and visible location is used.
- Inputs for different sensors
- Alarm output
- IP 65 protection
PORTABLE DATA LOGGER - MANY FUNCTIONS
Ideal data logger for overall analysis.
- Excellent price
- Web interface
- Colour touch screen
- Simple connection without setup
- Connectable sensors for all required measured quantities ( air flow, air consumption, energy consumption, pressure, temperature and more )
- Up to 24 inputs via expansion boxes and Modbus
- Multiple records can be combined
- Easy connection to third party devices
What to do in case of poor air quality?
More informationContact us
RECTANA s.r.o.
- Tloskovská 239,
257 56 Neveklov - IČ: 06451179
DIČ: CZ06451179
The company RECTANA s.r.o. is registered in the Commercial Register maintained by the Municipal Court in Prague, Section C, Insert 282293.